Basket

Products in your basket: 0

Amount: €0.00

On-Line Measurement

Page 8 of 39 (Products 71-80 of 384)
Attribute Selection WizardWhat does the 'Attribute Selection Wizard' do
What does 'POA' mean
 
VARiONPlus A Comp Set, NH4
Part No: X-107060

71.VARiONPlus A Comp Set, NH4

Ammonium measurement with automatical compensation of interfering ions (Potassium) Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of ammonium to be connected to the IQ SENSOR NET multiparameter measuring system - Integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 ammonium measuring electrode * 1 compensation-electrode (Potassium) Reference electrode ...

Price: POA
VARiONPlus N Comp Set, NO3
Part No: X-107062

72.VARiONPlus N Comp Set, NO3

Nitrate measuring with automatical compensation of interfering ions (Chloride) Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of Nitrate to be connected to the IQ SENSOR NET multiparameter measuring system - Integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 nitrate measuring electrode * 1 compensation electrode (Chloride) Reference electrode with po...

Price: POA
VARiONPlus AN/ A Comp Set NH4&NO3
Part No: X-107066

73.VARiONPlus AN/ A Comp Set NH4&NO3

Ammonium measurement with automatical compensation of interfering ions (Potassium) as well as additional measurement of Nitrite Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of ammonium and nitrate - To be connected to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 ammonium measuring electrode...

Price: POA
VARiONPlus AN/N Comp Set NH4&NO3
Part No: X-107068

74.VARiONPlus AN/N Comp Set NH4&NO3

Nitrate measuring with automatical compensation of interfering ions (Chloride) as well as additional measurement of ammonium Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of nitrate and ammonium to be connected to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 nitrate measuring electrode * 1 ...

Price: POA
AmmoLyt Plus 700 IQ
Part No: X-107070

75.AmmoLyt Plus 700 IQ

Ammonium armature with temperature measurement Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital ammonium sensor for installation of an ammonium replacement electrode, an ammonium reference electrode and a compensation electrode - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low imped...

Price: POA
AmmoLyt Plus Set
Part No: X-107071

76.AmmoLyt Plus Set

Ammonium armature with temperature measurement, ammonium replacement electrode and ammonium reference electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital ammonium sensor for installation of an a compensation electrode - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedanc...

Price: POA
AmmoLyt Plus Set/Comp
Part No: X-107072

77.AmmoLyt Plus Set/Comp

Ammonium armature with temperature measurement, ammonium replacement electrode, ammonium reference electrode and compensation electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital ammonium sensor - For connection to the IQ SENSOR NET multiparameter measuring system - Integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signal transmission - The...

Price: POA
NitraLyt Plus 700 IQ
Part No: X-107080

78.NitraLyt Plus 700 IQ

Nitrate armature with temperature measurement Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital nitrate sensor for installation of a nitrate replacement electrode, a reference electrode and a compensation electrode - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor. Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signal t...

Price: POA
NitraLyt Plus Set
Part No: X-107081

79.NitraLyt Plus Set

Nitrate armature with temperature measurement, nitrate replacement electrode and nitrate reference electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital nitrate sensor for installation of a compensation electrode. - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signa...

Price: POA
NitraLyt Plus Set/Comp
Part No: X-107082

80.NitraLyt Plus Set/Comp

Nitrate armature with temperature measurement, nitrate replacement electrode, nitrate reference electrode and compensation electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital nitrate sensor - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signal transmission - Th...

Price: POA
Page 8 of 39 (Products 71-80 of 384)