PB 150-2/1-115 V Stationary Sampler (Part No: X-000166)
Fully automatic stationary sampler for discontinuous sampling according to time, flow and events for free standing installation, 115 V.
Housing:
- Stainless steel (WKst. 4301) with 40mm hard foam insulation
- Separated wet section and control section
- Sample compartment temperature-controlled to 4 ... 6 °C with recirculation air
- Maintenance-free cooling unit with:
* CHC free refrigerant medium
* Automatic thawing device
* Heating
* 3-point control system with neutral zone
* Sun shield can be opened
- 4-point base
- Console or rack mounting.
Sampling system: Vacuum system with:
- Multifunction valve for the switching over of vacuum/pressure/ventilation
- Maintenance free and oil free vacuum pressure membrane pump with suction filter
- Suction power adjustable
* Medium suction speed >0.6m/sec at 5m suction height.
Dosage unit:
- Dosage vessel (Duran 50 glass)
- Conductive filling level electrodes in stainless steel (cond >50µS/cm)
- Motive pinch valve
Dosing quantity: Single sample volume adjustable in the range 20 ... 350 mL
Control:
- Microprocessor C-MOS control
- Watertight foil keypad
- 4 x 20 digit alphanumeric LCD display
- Key dialog operation
- Alternatively German or English
System program: Selectable, compact standard program
Program storage: 6 user programs
Program combinations: Time, flow, each combined with event
Time display: Date (WD, D, M, Y), Time (h, m, s)
Time preselection: Program start, Date/time with traceable bottle change
Time-dependent sampling: Interval in the range 0 ... 99:59 h
Sampling according to flow:
- Analog input / 0 ... 999.9 samplings per hour at 20mA
- Digital input / pulse divider 1 ... 9999
Bottle filling: According to time, 0 ... 99:59 h / sample-dependent 0 ... 999
Filling limitation: Max. no. of samples per bottle No / Yes from 0 to 999
Program repetition: No / Yes (permanent operation)
Manual sampling: During running program
Flow signal input:
- Analog 0/4-20mA/ via optocoupler
- Threshold voltage 3.3 V/150 Ohm at 20 mA
- 2-point calibration at 4 mA and 20 mA
Quantity scaling: None/m3/h
Event input: Potential free closer (>50mS)
Info memory:
- Max. 1000 entries
- Free selection of errors and events
- Graphic representation of 0/4-20 mA and temperature
Bottle: 25 l PE collection container (selection with ordering)
Retrofitting/extension:
- Simple retrofitting with distributor system to 2 x 13 L PE / 4 x 6.5 L PE / 12 x 2.9 L PE / 12 x 2.0 L glass / 24 x 1.1 L PE / 24 x 1.0 L glass
Option: Variable dosage unit for alternative operation according to flow-through
Option: RS232 interface operation via plug connection on the control unit housing (in combination with cable and PC program only)
Option: Signal outputs / operation/error message, program, program end, distributor
Sample pipeline:
- PVC
- Fiber-reinforced 1/2" (ID) with screw coupling
- Light-proof
- 5m long
Max. suction height / max. suction length: 7.5m (from dosage vessel) / 30m
Power supply :
- 115V
- 50/60Hz
- 5A
- Fuse 16A
- Shockproof socket
- In the case of permanent connection, with line separator
Overvoltage protection: All inputs
Environmental conditions:
- Operation - 20... + 40 °C / storage: - 25 ... + 50 °C
Weight: Approx. 90 kg - depending on design
Test certificates: CE