Ammonium measurement with automatical compensation of interfering ions (Potassium) Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of ammonium to be connected to the IQ SENSOR NET multiparameter measuring system - Integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 ammonium measuring electrode * 1 compensation-electrode (Potassium) Reference electrode ...
Nitrate measuring with automatical compensation of interfering ions (Chloride) Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of Nitrate to be connected to the IQ SENSOR NET multiparameter measuring system - Integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 nitrate measuring electrode * 1 compensation electrode (Chloride) Reference electrode with po...
3.VARiONPlus AN/ A Comp Set NH4&NO3
Ammonium measurement with automatical compensation of interfering ions (Potassium) as well as additional measurement of Nitrite Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of ammonium and nitrate - To be connected to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 ammonium measuring electrode...
4.VARiONPlus AN/N Comp Set NH4&NO3
Nitrate measuring with automatical compensation of interfering ions (Chloride) as well as additional measurement of ammonium Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M256 for meters to be used at waste water treatment plants Digital sensor for ion-selective measurements of nitrate and ammonium to be connected to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor - Dedicated for municipal and industrial waste water - With: * 1 reference electrode * 1 nitrate measuring electrode * 1 ...
Ammonium armature with temperature measurement, ammonium replacement electrode and ammonium reference electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital ammonium sensor for installation of an a compensation electrode - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedanc...
Ammonium armature with temperature measurement, ammonium replacement electrode, ammonium reference electrode and compensation electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital ammonium sensor - For connection to the IQ SENSOR NET multiparameter measuring system - Integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signal transmission - The...
Nitrate armature with temperature measurement, nitrate replacement electrode and nitrate reference electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital nitrate sensor for installation of a compensation electrode. - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signa...
Nitrate armature with temperature measurement, nitrate replacement electrode, nitrate reference electrode and compensation electrode Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital nitrate sensor - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signal transmission - Th...
pH/ORP sensor with temperature measurement Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256 Digital pH/ORP sensor - For installation of a pH or ORP combination electrode - For connection to the IQ SENSOR NET multiparameter measuring system - With integrated temperature sensor Equipped with the following features: - Integrated lightning protection - Sensor with integrated preamplifier for low impedance signal transmission - Sensor monitoring function (Sens-Ch...
SensoLyt® 700 IQ SW Robust digital pH/ORP sensor for SensoLyt® SEA/DWA/ECA/PtA pH/ORP electrodes - Sea water design - For use with the IQ SENSOR NET - SensCheck function detects glass breakage - In-sensor memory for storage of calibration data - Easy exchange of electrode - Coarse and fine lightning protection - Automatic temperature compensation - Ambient conditions: 0°C...60°C - Built-in pre-amplifier and temperature sensor (NTC) - With SensCheck function - Without connection cable (Please order SACIQ separately)