Photometric test kit for measurement of Nitrate NO3 Available ranges: 0.5 - 18.0 mg/l NO3-N 2.2 - 79.7 mg/l NO3 Number of tests: 25 (Reaction cuvettes test) Sample volume required: 1.5ml Cuvette type: round Compatible with photometers: photoLab S6 photoLab S12 photoLab Spectral pHotoFlex 0.5 - 14.5 mg/l NO3-N2.2 - 64.2 mg/l NO3 Additional information: Reference CombiCheck test available. Reaction: Model 14542 and 14773: nitrospectral; Models N1/25, 14764, 09713 and 00614: DMP analog to DIN 38405 D9/ISO 7890; Models 14556 and 14942: phenol derivative (suitable for sea ...
Photometric test kit for measurement of Nitrate NO3 Available ranges: 0.10 - 3.00 mg/l NO3-N 0.44 - 13.30 mg/l NO3 Number of tests: 25 (Reaction cuvettes test) Sample volume required: 2ml Cuvette type: round Compatible with photometers: photoLab S12 photoLab Spectral pHotoFlex 0.10 - 2.70 mg/l NO3-N; 0.44 - 11.95 mg/l NO3 Additional information: Reference CombiCheck test available. For use with seawater. Reaction: Model 14542 and 14773: nitrospectral; Models N1/25, 14764, 09713 and 00614: DMP analog to DIN 38405 D9/ISO 7890; Models 14556 and 14942: phenol derivative (...
Photometric test kit for measurement of Phenol C6H5OH Available ranges: 0.10 - 2.50 mg/l C6H5OH Number of tests: 25 (Reaction cuvettes test) Sample volume required: 10ml Cuvette type: round Compatible with photometers: photoLab S12 photoLab Spectral Additional information: For use with seawater. Reaction: 4-Amoniantupyrin analog ISO 6439 / US Standard Methods 5530, EPA 420.1 (00856); SMBTH (14551) Applications: Wastewater, surface water
Photometric test kit for measurement of Phosphate PO4 Available ranges: 0.5 - 25.0 mg/l PO4-P 1.5 - 76.7 mg/l PO4 Number of tests: 25 (Reaction cuvettes test) Sample volume required: 5ml Cuvette type: round Compatible with photometers: photoLab S6 photoLab S12 photoLab Spectral pHotoFlex 0.5 - 25.0 mg/l PO4-P; 1.5 - 76.7 mg/l PO4 Additional information: Reference CombiCheck test available. For use with seawater. Reaction: Models P4/25, P5/25, 00616, 00798, 14543, 14729, 14848, PO4-1 TP, PO4-2,3 TC: phosphorus-molybdenum blue (PMB) analog to ISO 6878 and US Standard M...
Photometric test kit for measurement of Sulfate SO4 Available ranges: 5 - 250 mg/l SO4 Number of tests: 25 (Reaction cuvettes test) Sample volume required: 5ml Cuvette type: round Compatible with photometers: photoLab S6 photoLab S12 photoLab Spectral pHotoFlex 5 - 250 mg/l SO4 Additional information: Reference CombiCheck test available. For use with seawater. Reaction: Models 14548, 14564 and 00617, SO4-1 TP: barium sulfate, turbidometric, analog US Standard Method 4500-SO42- E/IPA 375.4.; Model 14791: tannin Applications:Ground water, building materials, soils
Photometric test kit for measurement of Sulfate SO4 Available ranges: 100 - 1000 mg/l SO4 Number of tests: 25 (Reaction cuvettes test) Sample volume required: 1ml Cuvette type: round Compatible with photometers: photoLab S6 photoLab S12 photoLab Spectral Additional information: Reference CombiCheck test available. For use with seawater. Reaction: Models 14548, 14564 and 00617, SO4-1 TP: barium sulfate, turbidometric, analog US Standard Method 4500-SO42- E/IPA 375.4.; Model 14791: tannin Applications:Ground water, building materials, soils
Photometric test kit for measurement of Sulfite SO3 Available ranges: 1.0 - 20.0 mg/l SO3 Number of tests: 25 (Reaction cuvettes test) Sample volume required: 3ml Cuvette type: round Compatible with photometers: photoLab S12 photoLab Spectral Additional information: Reaction: Ellman"s reagent Applications: Wastewater, boiler water, foodstuffs Note: Range of sensitivity 0.05 – 3.00 mg/l SO3
Photometric test kit for measurement of Zinc Zn Available ranges: 0.20 - 5.00 mg/l Zn Number of tests: 25 (Reaction cuvettes test) Sample volume required: 0.5ml Cuvette type: round Compatible with photometers: photoLab S6 photoLab S12 photoLab Spectral pHotoFlex 0.20 - 5.00 mg/l Zn Additional information: Reference CombiCheck test available. Reaction: Model 14832: Cl-PAN. Models 14566, 00861: PAR Applications: Wastewater, particularly from electroplating and metal processing industries, seepage water, sewage sludge, soils
Photometric test kit for measurement of Chlorine Cl2 Available ranges: 0.03 - 6.00 Cl2 Number of tests: 200 (Reaction cuvettes test) Sample volume required: 5ml Cuvette type: round Compatible with photometers: photoLab S6 photoLab S12 photoLab Spectral pHotoFlex 0.05 - 5.00 Cl2 Additional information: Reaction: DPD analog DIN 38408 G4, EN ISO 7393 Applications: Disinfectants, wastewater, drinking water Note: Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When t...
Photometric test kit for measurement of Chlorine Cl2 Available ranges: 0.03 - 6.00 Cl2 Number of tests: 200* (Reaction cuvettes test) Sample volume required: 5ml Cuvette type: round Compatible with photometers: photoLab S6 photoLab S12 photoLab Spectral pHotoFlex 0.05 - 5.00 Cl2 Additional information: Reaction: DPD analog DIN 38408 G4, EN ISO 7393 Applications: Disinfectants, wastewater, drinking water Note: Cuvette test sets 00595 and 00597 contain 3 round cuvettes with bar-code labels. Preparation and measurement of the sample occurs in the round cuvette. When ...