Products in your basket: 0
Amount: €0.00
Online Shop » Chromatography » HPLC Columns » Inertsil
To view all 2248 products belonging to this category, click on the link here.

GL Sciences Inc. manufactures the world renowned Inertsil® rangeof hplc Columns.
Inertsil® hplc columns offer exceptional physical and chemicalstability resulting in outstanding chromatographic peak shape and long termcolumn performance.
There is now over 2,000 GL Science, InertsilHPLC products available at carlstuart.com.
Inertsil® hplc columns can be classified into a number of families as follows:
The original 2-Series Inertsil phases, including Inertsil®ODS-2 (Octadecyl), Inertsil®C8 (Octyl), Inertsil® Ph (Phenyl), Inertsil® C4 (Butyl ,and Inertsil® SIL-150A, createdthe high purity silica revolution in the late 1980s. These phases utilizea 99.999% pure silica which is extremely durable and free from dents and cracks- which can cause premature column failure.
By choosing Inertsil ODS-2 series columns, you can beassured that you are using some of the most trusted, popular, andenduring HPLC columns in the history of HPLC.
The original Inertsil 2-Series of columns remain some of themost useful and popular on the market today. However, GL Sciences' Inertsil3-Series phases were a major advancement on the original 2-Series, andgenerally provide superior chromatography and alternative selectivity to the2-Series. We recommend starting out with Inertsil®ODS-3 or Inertsil®ODS-3V for new methods using an ODS (C18) phase.
GL Sciences has compiled a vast collection of chromatographic applications data onODS-2 and their other phases which can assist you in method development.
GL Sciences' Inertsil® ODS-80A was originally introduced to provide a higher surface areaalternative to Inertsil®ODS-2, but with the same inertness and base-deactivatedproperties. However, Inertsil ODS-80A was quickly followed by therelease of Inertsil®ODS-3 , which proved far superior to both the ODS-2 phase andODS-80A. While GL Sciences continues to produce Inertsil ODS-80A tosupport customerĂ¢€â„¢s methods on this material, we DO NOT RECOMMEND this phasefor NEW APPLICATIONS.
By choosing Inertsil ODS-2 series columns, you can beassured that you are using some of the most trusted, popular, andenduring HPLC columns in the history of HPLC.
|
The Inertsil 3-series represents a major advance inperformance over the original Inertsil 2-Series. Inertsil 3-Series phases arebased on a purer, higher surface area silica which is specially manufactured toprovide maximum bonded phase coverage. The result is a series of columnswhich provide excellent peak shapes using simple eluents while operating at lowpressure.
Inertsi 3-Series isavailable in a wide range of bonded phases, including ODS-3, ODS-3V, ODS-Sprint for reduced retention of non-polarcompounds, C8-3, Phenyl-3, ODS-EP containing an embedded polar group forincreased retention of polar compounds, CN-3, HILIC, NH2, Diol, and aPolymerically bonded ODS-P phase with unique selectivity for planar compounds.ODS-P was uniquely designed for analysis of 16 priority PAHs in environmentalsamples but has also found to be useful for pharmaceutical analysis of planarcompounds.
Inertsil ODS-3, alongwith most of the other Inertsil 3-series phases, are available in 3, 5, and 8micron particle sizes in column configurations ranging from capillary to 50mmID preparative sizes.
GL Sciences hascompiled a vast collection of chromatographicapplications data on ODS-3 and their other phases which can assist you inmethod development. These can be accessed under the"chromatograms" link on the main menu bar above, by searching for aparticular compound using our "search" link above, or by clicking here.
Inertsi 3-Series isavailable in a wide range of bonded phases, including ODS-3, ODS-3V, ODS-Sprint for reduced retention of non-polarcompounds, C8-3, Phenyl-3, ODS-EP containing an embedded polar group forincreased retention of polar compounds, CN-3, HILIC, NH2, Diol, and aPolymerically bonded ODS-P phase with unique selectivity for planar compounds.ODS-P was uniquely designed for analysis of 16 priority PAHs in environmentalsamples but has also found to be useful for pharmaceutical analysis of planarcompounds.
Inertsil ODS-3, alongwith most of the other Inertsil 3-series phases, are available in 3, 5, and 8micron particle sizes in column configurations ranging from capillary to 50mmID preparative sizes.
By choosing InertsilODS-3 , you can be assured that you are using one of the most trusted,popular, and enduring HPLC columns in the history of HPLC.
In the chromatogram below, an Inertsil ODS
|
The new Inertsil WP300 series of columns brings the same legendaryperformance of Inertsil's narrow-pore HPLC products to columns designed forprotein and peptide analysis. The WP300 series currently consists of WP300C8,WP300C18, WP300Diol, WP300C4, WP300SIL and PeptideC18. .
Inertsil WP300 C4columns are typically used for analysis of large proteins or very hydrophobicproteins which are too highly retained on C8 or C18 phases.
Inertsil WP300 columns are available in 5 micron particle size incolumn configurations
ranging from capillary to 50mm ID preparative sizes.
( Wide Pore Columns for Protein andPeptide Chromatography )
Inertsil ODS-3, alongwith most of the other Inertsil 3-series phases, are available in 3, 5, and 8micron particle sizes in column configurations ranging from capillary to 50mmID preparative sizes.
By choosing InertsilODS-3 , you can be assured that you are using one of the most trusted,popular, and enduring HPLC columns in the history of HPLC.
|